Λεπτομέρειες προιόντος
Place of Origin: China
Μάρκα: BRANS
Model Number: WL-111
Όροι πληρωμής & ναυτιλίας
Feature: |
Off Center Load Cell |
Structure: |
Single Point Type |
Sensitivity: |
2mv/v |
Input Resistance: |
400±10Ω |
Ultimate Overload: |
200%FS |
Safe Load Limit: |
150% |
Precision: |
C3 |
Theory: |
Strain Gauge |
Feature: |
Off Center Load Cell |
Structure: |
Single Point Type |
Sensitivity: |
2mv/v |
Input Resistance: |
400±10Ω |
Ultimate Overload: |
200%FS |
Safe Load Limit: |
150% |
Precision: |
C3 |
Theory: |
Strain Gauge |
A Single-Point Load Cell is a type of load cell specifically designed for applications that require precise weight measurement in a single point. These load cells are commonly used in various industries for tasks such as checkweighing, batching, and other weighing applications that demand accuracy and reliability.
One of the key features of the Single-Point Load Cell is its miniature size, making it ideal for installations where space is limited. Despite its compact design, this load cell offers high performance and accuracy, ensuring consistent and reliable weight measurements.
The Single-Point Load Cell comes with a cable length ranging from 2 to 5 meters, providing flexibility in installation and ensuring that it can be easily integrated into different systems and setups. This makes it suitable for a wide range of weighing applications across various industries.
With an IP Class rating of IP65, the Single-Point Load Cell is well-protected against dust and water ingress, making it suitable for use in challenging environments where exposure to moisture or particles may be a concern. This ensures the longevity and durability of the load cell, even in demanding operating conditions.
When it comes to capacity, the Single-Point Load Cell offers a range from 2kg to 50kg, catering to a variety of weighing needs across different industries. Whether it's for light-duty or heavy-duty applications, this load cell provides accurate and consistent weight measurements within its specified capacity range.
Another noteworthy feature of the Single-Point Load Cell is its off-center load cell design, which allows for accurate weight measurement even when the load is not perfectly centered on the weighing platform. This feature ensures reliable performance in real-world scenarios where loads may be positioned off-center during weighing operations.
In summary, the Single-Point Load Cell is a versatile and reliable weighing solution that offers precision and accuracy in a compact form factor. With its miniature size, flexible cable length, IP65 protection, wide capacity range, and off-center load cell design, it is a valuable tool for various industries that require a Single-Point Weight Measuring Device for their weighing applications.
Feature | Off Center Load Cell |
Cable Length | 2-5 Meters |
Customized | Acceptable |
Ultimate Overload | 200%FS |
Input Resistance | 400±10Ω |
Sensitivity | 2mv/v |
Structure | Single Point Type |
IP Class | IP65 |
Precision | C3 |
Safe Load Limit | 150% |
The BRANS WL-111 Single Point Load Cell is a high-quality product designed for various applications that require precise weight measurements. This single-point force transducer is ideal for use in Single-Point Weight Measuring Devices, offering accurate and reliable results.
Manufactured in China, the BRANS WL-111 load cell boasts a sturdy construction using aluminum alloy, ensuring durability and long-lasting performance. With an input resistance of 400±10Ω, this load cell provides stable and consistent readings across different environments.
The ultimate overload capacity of 200%FS makes the WL-111 load cell suitable for demanding scenarios where sudden spikes in weight may occur. Additionally, the safe load limit of 150% ensures the safety of the load cell and the overall measuring system.
Thanks to its single-point design, this load cell is perfect for applications that require a Single-Point Weight Measuring Device setup. The cable length of 2-5 meters offers flexibility in installation, making it suitable for a wide range of scenarios.
Whether used in industrial settings, laboratories, or commercial applications, the BRANS WL-111 Single Point Load Cell delivers accurate and precise weight measurements consistently. Trust in the reliability and performance of this load cell for all your single-point force transducer needs.
Product Customization Services for the Single Point Load Cell:
Brand Name: BRANS
Model Number: WL-111
Place of Origin: China
Customized: Acceptable
Ultimate Overload: 200%FS
Structure: Single Point Type
IP Class: IP65
Sensitivity: 2mv/v
Product Packaging:
Our Single Point Load Cell is carefully packaged to ensure safe delivery to our customers. Each load cell is securely wrapped in protective material and placed in a sturdy cardboard box to prevent any damage during transportation.
Shipping: